Protection Class IP 64 opt.

- Definition of indexes -

6 (First index digit: Degree of contact prevention and guarding against foreign matter)
Total protection of persons from touching voltage-carrying or internal moving parts. Protection of the object from access of dust.

4 (Second index digit: Degree of water protection)
Water splashing against the object from all directions must not have any harmful effect.

opt. (Accessories required)

Necessary accessories: front panel F3.

Attention:
Our products with specification of protection classes have a particular design and are tested as unique object VDE and/or according to IEC 529.
For special modification or mounting with accessories we recommend a certification of the final products.